System Errors

Alarm Troubleshooting

Alarm and Description

Cause

Solution

 

 

 

CA

The CAN cable between the Display Mod-

Verify that the cable is correctly

Communication Error

ule and the Advanced Fluid Control Module

connected.

The Display Module is not

is not connected.

 

communicating with the

 

 

The CAN cable is cut or bent.

Verify that the cable has not been cut

Advanced Fluid Control

 

or bent at a radius smaller than 1.6 in.

Module.

 

(40 mm).

 

 

 

 

The cable or connector failed.

Replace cable.

 

 

 

 

Alternator Powered Systems:

1. For any module that does not

 

Check that the Advance Fluid Control Mod-

have power, disconnect and

 

check the voltage on the cable

 

ule (AFCM), Display Module (DM), and

produced by the alternator mod-

 

USB Module have power (green LED) and

ule (See Alternator Module Power

 

are communicating (amber LED blinking)

Output). If the proper voltage is

 

 

not detected, troubleshoot the

 

 

Alternator Module.

 

 

2. If the proper voltage is detected,

 

 

verify the cable connecting the

 

 

two modules is good.

 

 

3. If the cable is good, replace the

 

 

module.

 

 

 

 

There may be a short in one of the sole-

Replace the cable (16E890)

 

noid/meter cables connected to the AFCM.

 

 

 

 

 

The AFCM power supply may be bad, as

Replace the module.

 

indicated by the status LEDs (red, yellow,

 

 

green) being off. Verify the power supply

 

 

works by disconnecting from the AFCM and

 

 

connecting to another module, either the

 

 

Display Module or USB Module.

 

 

 

 

 

The DM and the AFCM have different ver-

Install the latest software from token

 

sions of software installed.

kit 16D922 on all modules.

 

 

 

 

The red LED on the AFCM is on.

If on solid, replace module.

 

 

If blinking, contact your distributor.

 

 

 

 

NOTE:

 

 

1. If the AFCM loses communication (no flickering amber LED) but then comes

 

back on the alarm will auto clear and will not log the alarm.

 

2. If the DM loses communication (no flickering amber LED) but then comes back

 

on you will have to manually clear the alarm and there will be an alarm log.

 

3. If the USB module loses communication (no flickering amber LED) but then

 

comes back on you will not get an alarm.

 

 

 

CAU1

The module has been removed.

Put system in standby and install the

USB Communication Error

 

USB Module.

The system detected a USB

 

 

The cable is disconnected or broken.

Put system in standby and reconnect

Module at last power up, but

 

or replace the USB cable.

does not detect it currently.

 

 