Setup Mode Details
Maintenance 1-3 (Screens 24-26)
Maintenance 1 (Screen 24) displays if is selected on Setup Home (Screen 17). The Maintenance Screens display actual and target maintenance timers for pumps and solvent valves (Maintenance 1, Screen 24), dose valves (Maintenance 2, Screen 25), and fluid filters and air filters (Maintenance 3, Screen 26). Maintenance tim- ers for pumps and valves are settable from 0 to 9999999. Timers for filters are settable from 0 to 9999 days.
Solvent valves
Pumps
Maintenance actual and target
Maintenance 1
Clear Home
Totals
Dose valves
Maintenance 2
Air filter
Fluid
filters | Days |
Maintenance 3
FIG. 42. Setup Maintenance 1-3 (Screens 24-26)
•Press to move through the three mainte- nance screens.
•Press to clear the maintenance total that is highlighted. A verification screen appears. Use
to highlight and press on the to clear the batch totals. No other button press will clear the
totals. Press on the to return to the active Maintenance Screen without clearing.
Maintenance Recommendations
The following table shows recommended starting values for maintenance. Maintenance needs will vary based on individual applications and material differences.
| Recommended Maintenance |
Component | Frequency |
|
|
Solvent Valves | 1,000,000 cycles |
|
|
Fluid Filter | daily |
|
|
Air Filter | monthly |
|
|
Pumps | 250,000 cycles |
|
|
Dose Valves | 1,000,000 cycles |
|
|
3A0868G | 45 |