Display Module

Screen Summary

NOTE: This summary is a one-page guide to the ProMix 2KE screens, followed by screen maps. For operating instructions, see Basic Operation, page 29. For further detail on individual screens, see Run Mode Details, page 39, or Setup Mode Details, page 42.

Run Mode

The run mode has three screen sections that control the mixing operations.

Mix (Screens 2-4, 38)

Spray (Screen 2) controls most mixing opera- tions.

Batch (Screen 3) controls dispense of a set vol- ume.

Totals (Screen 4) displays grand and batch totals for materials A and B.

Job Number (Screen 38) displays job number and user number

Error Log (Screens 5-14)

10 screens, 5 errors per page.

Displays date, time, and error.

Pump Control (Screen 15)

Manually start or stop a pump.

Park pumps for brief shutdowns.

Setup Mode

The setup mode has four screen sections that allow an authorized user to choose the exact settings needed for the system:

Configure (Screens 18-21)

Configure 1 (Screen 18) controls system type (pump or meter), gun flush box enable, and number of guns (1 or 2).

Configure 2 (Screen 19) controls hose length and diameter for one or two guns, flow rate region setting, and air flow switch enable or disable.

Configure 3 (Screen 20) controls language (for optional USB Module), date format, date, time, password setting, and backlight timer.

Configure 4 (Screen 21) controls units for dis- tance, volume and pressure.

Recipe (Screens 28 and 29)

Recipe 1-1 (Screen 28) and 1-2 (Screen 29) control Material 1/Color 1 parameters and flush.

Maintenance (Screens 24-26)

Maintenance 1 (Screen 24) controls mainte- nance timer actual and target for Pump A, Pump B, Solvent Valve A, and Solvent Valve B.

Maintenance 2 (Screen 25) controls dose valves A and B maintenance timers, actual and target.

Maintenance 3 (Screen 26) controls fluid and air filter maintenance timers, actual and target.

Calibration (Screens 22 and 23)

Calibration 1 (Screen 22) controls pump factors for Pump A and Pump B.

Calibration 2 (Screen 23) allows the user to per- form a calibration.

Troubleshooting

The troubleshooting mode has three screen sections that allow an authorized user to troubleshoot system operation. See FIG. 14, page 28.

System Inputs (Screen 35)

Membrane Test (Screen 36)

System Outputs and Manual Activation (Screen 37)