System Errors

Alarm and Description

Cause

Solution

 

 

 

DDA1 or DDB1

Fluid supply is empty.

Refill fluid supply system.

Diving/Cavitation Error

 

 

Displacement pump is not seating properly.

Rebuild displacement pump and

Pump A (DDA1) or Pump B

 

replace packings, balls, and seats.

(DDB1) is diving or cavitating.

 

 

 

Air in fluid supply system.

Tighten all fittings.

 

 

 

 

EFA1 or EFB1

Gun not open.

Trigger gun and allow fluid to flow

Park Error

 

while pump is attempting to park.

Pump A (EFA1) or Pump B

 

 

Fluid lines plugged.

Check and clear all fluid lines, gun tip,

(EFB1) does not park (does

 

and the mix manifold.

not reach bottom change-

 

 

Dispense valve malfunction.

Clean or rebuild dispense valve. Ver-

over).

 

ify that solenoid is operational. Clear

 

 

 

 

air lines to valve.

 

 

 

DFA1 or DFB1

Displacement pump is not seating properly.

Rebuild displacement pump and

Stall Up Error

 

replace packings, balls, and seats.

Pump A (DFA1) or Pump B

 

 

Dispense valve not seating/sealing.

Replace needle/seat on dispense

(DFB1) does not stall up dur-

 

valve.

ing the pump calibration and

 

 

stall test (keeps moving up

 

 

when dosing valve is closed).

 

 

 

 

 

DGA1 or DGB1

Displacement pump is not seating properly.

Rebuild displacement pump and

Stall Down Error

 

replace packings, balls, and seats.

Pump A (DGA1) or Pump B

 

 

Dispense valve not seating/sealing.

Replace needle/seat on dispense

(DGB1) does not stall down

 

valve.

during the pump calibration

 

 

and stall test (keeps moving

 

 

down when dosing valve is

 

 

closed).

 

 

 

 

 

DHA1 or DHB1

Displacement pump is not seating properly.

Rebuild displacement pump and

No Stall Error

 

replace packings, balls, and seats.

Pump A (DHA1) or Pump B

 

 

Dispense valve not seating/sealing.

Replace needle/seat on dispense

(DHB1) does not stall in either

 

valve.

direction during the pump cali-

 

 

bration and stall test (keeps

 

 

moving when dosing valve is

 

 

closed).

 

 

 

 

 