Setup Mode Details

Configure 1-4 (Screens 18-21)

Configure 1 (Screen 18) displays if is selected on Setup Home (Screen 17). This screen allows users to set up the system type (pump or meter) and number of guns (1 or 2).

NOTE: If 1 gun is selected, users can enable a gun flush box (=yes; X=no). The gun flush box option is avail- able only for 1-gun systems.

For all pump systems, the type of dosing is dynamic, and the number of colors is 1. See Dynamic DosingDy- namic Dosing, page 48, for more information.

FIG. 37. Confirm Change of System Type

Configure 2 (Screen 19) allows users to set for each gun the hose length (0.1 to 45.7 m, 0.3 to 150 ft) and hose diameter (0.1 to 1 inch). The system uses this informa- tion to calculate pot life volume. The pot life volume tells the system how much material must be moved to trigger a reset of the pot life timer. It also tells the system the

System type

Gun flush box

Number of guns

volume needed to fill during a load sequence.

Users also can configure the flow rate region and the air flow switch. The flow rate region (High/Low) determines the sensitivity of the overdose alarm:

Home

FIG. 36. Configure 1 (Screen 18)

Press to highlight the desired field. Press

to display the dropdown menu for that field.

Press to choose from the menu options and

to set. Press to move to the next field.

Press to move through Configure 2 (Screen 19), Configure 3 (Screen 20), and Configure 4 (Screen 21).

NOTE: If you change system type (pump to meter) or number of guns, a verification screen appears. Use

to highlight and press on the to make the change, or on the to return to Configure 1 (Screen

18)without making a change. If a change is made, the system locks so that you cannot spray or mix. Power down and power back up again to clear the lock and put the new settings into effect. The lock ensures that the selection was intended, and prevents the user from attempting to operate with incorrect settings.

Select the High setting if your flow rate is 250 cc/min or higher. The High setting has a 100cc over- dose volume.

Select the Low setting if your flow rate is less than 250 cc/min. The Low setting has a 50 cc over- dose volume.

The air flow switch can be disabled here for airless applications. Select to enable or to disable.

A change in any of these fields will trigger the lock. See NOTE in previous paragraph.

Gun 1

Gun 2

hose

hose

length

length

 

Gun 1

Gun 2

hose

hose

diameter

diameter

Air

Flow rate

flow

region

switch

 

Home

FIG. 38. Configure 2 (Screen 19)

Configure 3 (Screen 20) allows users to set preferred language (for optional USB Module), date format, date, time, password (0000 to 9999), and number of minutes (0 to 99) of inactivity required before the backlight turns off. Configure 4 (Screen 21) allows users to set pre- ferred units for distance, volume, and pressure.