Basic Operation

8.Purge as follows:

Purge component A side. Press the manual override on the Dose Valve A solenoid valve and trigger the gun into a grounded metal pail.

Purge component B side. Press the manual override on the Dose Valve B solenoid valve and trigger the gun into a grounded metal pail until clean solvent flows from the gun.

9.Reinstall the Control Box cover.

10.Shut off the solvent fluid supply.

11.Disconnect the solvent supply lines and reconnect the component A and B fluid supplies.

NOTE: The system remains full of solvent.

Repeat to thoroughly clean the mix manifold.

Manual overrides

Solvent Valve A

Solenoid

Dose Valve A

Gun Flush Box Solenoid

ti15730a

Solenoid

location, if used.

 

 

 

Solvent Valve B

Dose Valve B

 

Solenoid

Solenoid

 