Installation

Electrical

Power Connection (non-IS units only)

All electrical wiring must be completed by a qualified electrician and comply with all local codes and regulations.

Enclose all cables routed in the spray booth and high traffic areas in conduit to prevent damage from paint, solvent, and traffic.

The ProMix 2KE operates with 85-250 VAC, 50/60 Hz input power, with a maximum of 2 amp current draw. The power supply circuit must be protected with a 15 amp maximum circuit breaker.

Not included with system:

Power supply cord compatible to your local power configuration. Wire gauge size must be 8-14 AWG.

The input power access port is 22.4 mm (0.88 in.) in diameter. It accepts a bulkhead strain relief fitting or conduit.

1.Verify that electrical power at the main panel is shut off. Open Control Box cover.

2.Connect electrical cord to the terminal block as shown in FIG. 6.

3.Close the Control Box. Restore power.

4.Follow instructions in Grounding, page 19.

Line

Ground

Neutral

ti16391a

FIG. 6. Control Box Electrical Connection

TERMINAL

BLOCK

L N GRND

 

POWER

L GRND N

SUPPLY

LINE POWER

 

FILTER

 

LN

2A1A

SWITCH

ROCKER

21

FIG. 7. Electrical Schematic

18

3A0868G

Page 18
Image 18
Graco 3A0868G important safety instructions Electrical, Power Connection non-IS units only