Display Module

1.Use the screws provided to mount the bracket for the Display Module on the front of the Control Box or on the wall, as you prefer.

2.Snap the Display Module

into the bracket.

ti16672a

3.Connect one end of the CAN cable (provided) to J6 on the Display Module (either port).

ti16604a

J6

4.The other end of the cable

comes from the factory connected as shown, depending on the configuration of your system:

Installation

Air Supply

Requirements

Compressed air supply pressure: 75-100 psi (517-700 kPa, 5.2-7 bar).

Air hoses: use grounded hoses that are correctly sized for your system.

Trapped air can cause a pump or dispense valve to cycle unexpectedly, which could result in serious injury from splashing or moving parts. Use bleed-type shutoff valves.

Air regulator and bleed-type shutoff valve:

include in each air line to fluid supply equipment.

Install an additional shutoff valve upstream of all air

line accessories to isolate them for servicing.

Wall Power Systems with USB Module: Connect the CAN cable to P3 on the USB Mod- ule.

Wall Power Systems without USB Module: Connect CAN cable to J8 on the Advanced Fluid Control Module.

P3

ti16580a

J8

If using a Graco electrostatic PROGun, a shutoff valve must be installed in the gun air line to shutoff the atomizing and turbine air to the gun. Contact your Graco distributor for information on air shutoff valves for electrostatic applications.

Air line filter: a 10 micron or better air filter is rec- ommended to filter oil and water out of the air supply and help avoid paint contamination and clogged solenoids.

ti16579a

Alternator Power Sys- tems (with or without USB Module): Connect CAN cable to J3 on the alternator.

J3

ti16456a