Filter Tracking Mode (SP-8) (Continued)

Model EEE-141,142, 143, 144

6-1. SPECIAL PROGRAM MODE (Continued)

Filter Tracking Mode (SP-8) (Continued)

GLOBAL

If GLOBAL is selected, press Manual background button.

Split Vat

If unit is a split vat, “SP-8A” and “LEFT VAT FILTER CYCLES” shows in the left display, and the number of cook cycles between filters shows on the right display (0 to 99). Use Manual background and Manual background or product buttons to change this number.

Press button and “SP-8B” and “RIGHT VAT FILTER CYCLES” shows in the left display, and the number of cook cycles between filters shows on the right display (0 to 99).

Press button and “SP-8C” and “LOCKOUT ENABLED?”

shows in the left display. Press the Manual background and Manual background buttons to choose YES or NO.

If set to YES, press Manual background button and the left display shows “SP-8D” and “LEFT VAT LOCKOUT CYCLES” and the number of cook cycles before filter lock-out shows on the right

display (0 to 99). Use Manual background and Manual background or product buttons to change this number.

Press Manual background button and the left display shows “SP-8E” and “RGHT VAT LOCKOUT CYCLES” and the number of cook cycles before filter lock-out shows on the right display (0 to 99).

Use Manual background and Manual background or product numbers to change this number.

Once this number of cook cycles is reached, “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the display, and it refuses further cook cycles until the vat is filtered.

Full Vat

If unit is a full vat, “SP-8A” and “FULL VAT FILTER CYCLES” shows in the left display, and the number of cook cycles between filters shows on the right display (0 to 99). Use Manual background and Manual background or product numbers to change this number.

Press Manual background button and “SP-8B” and “LOCKOUT ENABLED?”

shows in the left display. Press the Manual background and Manual background buttons to choose YES or NO.

If set to YES, press Manual background button and the left display shows “SP-8C” and “FULL VAT LOCKOUT CYCLES” and the number of cook cycles before filter lock-out shows on the right display (0 to 99). Use and or product buttons to change this number.

Once this number of cook cycles is reached, “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the display, and it refuses further cook cycles until the vat is filtered.

6-5