DCP200 Profile Controller & Recorder - Product Manual

Clock Configuration Sub-Menu

 

Table 15. Internal Clock Configuration Sub-Menu Screens

 

 

 

 

Clock Configuration:

Date Format

 

w

Sets the format used for all displayed dates: dd/mm/yyyy (Day /

 

 

 

Month / Year) or mm/dd/yyyy (Month / Day / Year). – Recorder

 

 

 

versions only.

Set Date

 

w

Sets the internal clock Date. – Entered in the format defined by Date

 

 

 

Format screen. – Recorder versions only.

Set Day Of Week

 

 

Sets the day of week used by the internal clock. – Recorder versions

 

 

 

only.

Set Time

 

 

Sets the internal clock Time. - In hh:mm:ss (Hours : Minutes :

 

 

 

Seconds) format. – Recorder versions only.

Display Configuration Sub-Menu

Table 16. Display Configuration Sub-Menu Screens

Display Configuration:

 

Enable Custom Display

 

Enables/disables Custom Operation Mode, if configured (this mode

 

Mode

 

can only be enabled using the PC configuration software).

 

Read Only Operation

 

Allows Operation Mode to be Read-Only or Read/Write. Screens can

 

Mode?

 

be seen but values cannot be changed if set to Read-Only.

 

Operation Mode Bar

 

From: PID Power; Control Deviation or % Recorder Memory Usage.

 

Graph Format

 

 

 

Trend Sample Interval

 

Interval between display of next value on the trend graph From: Every

 

 

 

1; 2; 5; 10; 15; 30 Seconds, or Every 1; 2; 5; 10; 15; 30 Minutes.

 

Select Trend Mode

 

From: PV only, PV (solid) & SP (dotted) at sample time or Max/Min

 

 

 

PV between samples (candle-stick graph). Alarm activity is shown

 

 

 

above the trend graph.

 

Display Colour

 

From: Red only; Green only; Red to Green on Alarm or Green to Red

 

 

 

on Alarm.

 

Invert Display

 

Standard or Negative display image.

 

Display Contrast

 

Screen contrast (0 and 100) to improve clarity. 100 = maximum

 

 

 

contrast.

 

Language

 

Select English or the alternate local language. The alternate language

 

 

 

is selected at time of order. The choice of alternate language can be

 

 

 

changed using the PC software.

51-52-25-150, Issue 1 – April 2009

Configuration & Use

Page 55

Page 55
Image 55
Honeywell DCP200 manual Clock Configuration Sub-Menu, Display Configuration Sub-Menu

DCP200 specifications

The Honeywell DCP200 is an advanced distributed control platform designed to enhance efficiency, reliability, and flexibility in industrial automation. With a robust architecture capable of supporting a wide range of applications, the DCP200 is perfect for sectors including oil and gas, chemical processing, power generation, and manufacturing.

One of the key features of the Honeywell DCP200 is its scalability. It can be easily expanded to accommodate increasing demands, making it suitable for both small operations and large enterprises. This flexibility allows industries to adopt the system gradually, integrating it into their existing processes without substantial downtime or a steep learning curve.

The DCP200 is built on open standards, facilitating seamless integration with third-party systems and equipment. This compatibility ensures that companies can leverage existing infrastructures and investments, fostering a more cohesive operational environment. Enhanced interoperability is achieved via industry-standard communication protocols, enabling devices to communicate fluently across diverse platforms.

Another significant characteristic of the DCP200 is its powerful data acquisition and processing capabilities. The system utilizes state-of-the-art data analytics tools to monitor real-time information, enabling better decision-making and predictive maintenance. This proactive approach helps in reducing downtime, optimizing performance, and ultimately driving operational excellence.

The DCP200 system supports a wide range of input and output options, ensuring it can interface with various sensors, actuators, and control devices. This adaptability contributes to its function as a central hub for industrial monitoring and control, enhancing data visibility and operational responsiveness.

Security is a top priority for Honeywell, and the DCP200 employs robust cybersecurity measures to protect critical infrastructure. The system includes advanced authentication protocols and data encryption techniques, safeguarding sensitive information from unauthorized access and potential cyber threats.

User experience is also a focal point of the DCP200. The platform features an intuitive graphical user interface that simplifies navigation and enhances operator engagement. Customizable dashboards provide at-a-glance insights into system performance, aiding both operators and management in identifying areas for improvement.

In conclusion, the Honeywell DCP200 is an innovative distributed control platform that marries flexibility, scalability, and security. With its comprehensive feature set and commitment to seamless integration, it stands as a vital tool for companies aiming to enhance their automation efforts and drive operational success in an increasingly complex industrial landscape.