DCP200 Profile Controller & Recorder -Product Manual
51-52-25-150, Issue 1 April 2009 Configuration & Use Page 61
Profiler Control Menu
Table 21. Profiler Control Menu Screens
Profiler Menu:
Profile Control If a profile is running, choose from: Do Nothing, Abort Profile (end
immediately); or Jump to Next Profile Segment, Hold Profile or
Release Hold.
If no profile is running, choose from: Do Nothing, Run Profile or End
Profile Control (Return to normal controller operation).
Select Active Profile Change the active profile. Choose from the list of profile names
provided. The active profile is the profile that will run, when a run
instruction is given (perhaps via a digital input).
Select A Profile To Run Choose the profile to run from the list of names provided. The profile
name and run status is then confirmed.