DCP200 Profile Controller & Recorder - Product Manual

The following rules apply when creating a profile over communications:

Profiles must always be terminated with an end segment.

Segments cannot be added after an end segment has been added.

All changes made to the selected profile are immediately saved in the instrument.

Creating Or Editing A Profile Header

Creating Or Editing A Profile Header - Request (to instrument)

 

 

Field Name

 

Data

 

 

Comments

 

 

 

 

 

(Dec)

 

 

(Hex)

 

 

 

 

 

 

Unit Address

 

A/R

 

 

A/R

 

The ID address of the instrument.

 

 

Function Code

23

 

17

 

 

Requires the multi read/write function.

 

 

Read Start Address High Byte

32

 

20

 

 

 

 

 

 

Read Start Address Low Byte

06

 

06

 

 

 

 

 

 

Read Quantity Of Registers High Byte

00

 

00

 

 

 

 

 

 

Read Quantity Of Registers Low Byte

01

 

01

 

 

 

 

 

 

Write Start Address High Byte

32

 

20

 

 

 

 

 

 

Write Start Address Low Byte

06

 

06

 

 

 

 

 

 

Write Quantity Of Registers High Byte

00

 

00

 

 

 

 

 

 

Write Quantity Of Registers Low Byte

19

 

13

 

 

 

 

 

 

Byte Count

 

38 or 40

 

 

26 or 28

 

38dec / 0x26hex if creating a profile at the

 

 

 

 

 

 

 

 

 

 

next available location.

 

 

 

 

 

 

 

 

 

 

40dec / 0x28hex if creating a profile at a

 

 

 

 

 

 

 

 

 

 

specified location, or editing a profile.

 

 

Command Code High Byte

 

67, 69 or

 

 

43, 45 or

 

Create Profile (CP) = 67dec / 0x43hex

 

 

 

87

 

57

 

 

Edit Profile (EP) = 69dec / 0x45hex

 

 

 

 

 

 

 

 

 

 

Write Profile (WP) = 87dec / 0x57hex

 

 

Command Code Low Byte

80

 

50

 

 

 

 

 

 

Profile Number High Byte

 

A/R

 

 

A/R

 

Note: The profile number is not included

 

 

 

 

 

 

 

 

 

in the message when creating a profile

 

 

Profile Number Low Byte

 

A/R

 

 

A/R

 

 

 

 

 

 

 

 

 

 

 

at the next available position.

 

 

Profile Name Character 1

 

A/R

 

 

A/R

 

The ASCII codes equivalent to each of the

 

 

Profile Name Character 2

 

A/R

 

 

A/R

 

16 characters of the profile name, e.g. :

 

 

Profile Name Character 3

 

A/R

 

 

A/R

 

A = 65dec / 0x41, B = 66dec / 0x42 etc

 

 

 

 

 

 

 

 

 

 

a = 97dec / 0x61, b = 98dec / 0x62 etc

 

 

Profile Name Character 4

 

A/R

 

 

A/R

 

 

 

 

 

 

 

Note: Only valid characters from the

 

 

Profile Name Character 5

 

A/R

 

 

A/R

 

 

 

 

 

 

 

 

 

 

 

instruments supported character set

 

 

Profile Name Character 6

 

A/R

 

 

A/R

 

 

 

 

 

 

 

should be used

 

 

Profile Name Character 7

 

A/R

 

 

A/R

 

 

 

 

 

 

 

 

 

 

 

Profile Name Character 8

 

A/R

 

 

A/R

 

The space character (32dec / 0x20hex) is

 

 

Profile Name Character 9

 

A/R

 

 

A/R

 

 

 

 

 

 

 

used to fill any unused characters at the

 

 

Profile Name Character 10

 

A/R

 

 

A/R

 

end of the name.

 

 

Profile Name Character 11

 

A/R

 

 

A/R

 

 

 

 

 

Profile Name Character 12

 

A/R

 

 

A/R

 

 

 

 

 

Profile Name Character 13

 

A/R

 

 

A/R

 

 

 

 

 

Profile Name Character 14

 

A/R

 

 

A/R

 

 

 

 

 

Profile Name Character 15

 

A/R

 

 

A/R

 

 

 

 

 

Profile Name Character 16

 

A/R

 

 

A/R

 

 

 

 

 

Profile Start Signal High Byte

00

 

00

 

 

0 = No delay, 1 = After delay, 2 = At

 

 

 

 

 

 

 

 

 

 

 

 

Page 116

Modbus Parameters

51-52-25-150, Issue 1 – April 2009

Page 116
Image 116
Honeywell DCP200 manual Creating Or Editing a Profile Header, Field Name Data Comments

DCP200 specifications

The Honeywell DCP200 is an advanced distributed control platform designed to enhance efficiency, reliability, and flexibility in industrial automation. With a robust architecture capable of supporting a wide range of applications, the DCP200 is perfect for sectors including oil and gas, chemical processing, power generation, and manufacturing.

One of the key features of the Honeywell DCP200 is its scalability. It can be easily expanded to accommodate increasing demands, making it suitable for both small operations and large enterprises. This flexibility allows industries to adopt the system gradually, integrating it into their existing processes without substantial downtime or a steep learning curve.

The DCP200 is built on open standards, facilitating seamless integration with third-party systems and equipment. This compatibility ensures that companies can leverage existing infrastructures and investments, fostering a more cohesive operational environment. Enhanced interoperability is achieved via industry-standard communication protocols, enabling devices to communicate fluently across diverse platforms.

Another significant characteristic of the DCP200 is its powerful data acquisition and processing capabilities. The system utilizes state-of-the-art data analytics tools to monitor real-time information, enabling better decision-making and predictive maintenance. This proactive approach helps in reducing downtime, optimizing performance, and ultimately driving operational excellence.

The DCP200 system supports a wide range of input and output options, ensuring it can interface with various sensors, actuators, and control devices. This adaptability contributes to its function as a central hub for industrial monitoring and control, enhancing data visibility and operational responsiveness.

Security is a top priority for Honeywell, and the DCP200 employs robust cybersecurity measures to protect critical infrastructure. The system includes advanced authentication protocols and data encryption techniques, safeguarding sensitive information from unauthorized access and potential cyber threats.

User experience is also a focal point of the DCP200. The platform features an intuitive graphical user interface that simplifies navigation and enhances operator engagement. Customizable dashboards provide at-a-glance insights into system performance, aiding both operators and management in identifying areas for improvement.

In conclusion, the Honeywell DCP200 is an innovative distributed control platform that marries flexibility, scalability, and security. With its comprehensive feature set and commitment to seamless integration, it stands as a vital tool for companies aiming to enhance their automation efforts and drive operational success in an increasingly complex industrial landscape.