Overview of Navigation and Controls

PTZ Setup

The camera video should be in the current screen. Before setup, check whether the following connections are right:

Note

PTZ and decoder connection

 

Decoder address setup

Decoder A (RS485 +) / B (RS485 -) line connects with DVR A/B line

Boot up the DVR, and input the user name and password.

In the main menu, select SettingPan/Tilt/Zoom. The interface is shown as in Figure 4-29.Here you can set the following items:

Channel: Select the channel connected with the speed dome video port.

Protocol: Select the corresponding PTZ protocol (such as PELCOD).

Address: Identical to the device address set in the speed dome. Default address is 1.

Baud rate: Select corresponding baud rate. 2400 for Pelco-D protocol.

Data bits: Select corresponding data bits. Default value is 8.

Stop bits: Select corresponding stop bits. Default value is 1.

Parity: There are three options: Odd/Even/None. The default value is none.

54

Page 68
Image 68
Honeywell HD-DVR-1016, HD-DVR-1004, HD-DVR-1008 user manual PTZ Setup