Web Client Operation

Parameter

Function

 

 

 

Event Type

There are three types: Motion detection/video loss/Camera

Masking.

 

 

 

 

 

Channel

Select channel name from the dropdown list, and check the

checkbox beside it to enable its motion detection function.

 

Sensitivity

There are six levels.

The sixth level has the highest

sensitivity.

 

 

 

 

 

 

There are six levels. The sixth level has the highest

 

sensitivity.

 

 

Region: If you select motion detection type, you can click this

Region

button to set motion detection zone. The interface is shown in

Figure 6-40.There are PAL 22X18/NTSC 22X15 zones.

 

 

Right-click and you can go to the full-screen display mode. Do

 

remember to click OK to save your motion detection zone

 

setup.

 

 

Motion detection function becomes activated in the specified

 

periods.

 

 

There are six periods in one day. Please check the checkbox

Period

to enable corresponding period.

Select date. If you do not, the current setup applies to today

 

only. You can select all week column to apply to the whole

 

week.

 

 

Click OK, and the system goes back to motion detection

 

interface; please click Save to exit.

Anti-dither

Not Effective in the current DVR version.

 

 

 

There is 3-channel alarm output.

 

Corresponding to motion detection alarm output port (multiple

Alarm out

choices)

 

Enable alarm activation function. You need to select alarm

 

 

output port so that the system can activate the corresponding

 

alarm device when an alarm occurs.

 

 

Alarm latch

System can delay the alarm output for a specified time after a

detection event ends. The value ranges from 10s to 300s.

 

 

System auto activates motion detection channel (multiple

 

choices) to record once alarm occurs (working with motion

Record

detection function). Please note you need to go to the chapter

channel

Motion Detection to set motion detection record period and go

 

to the chapter Manual Record to set the current period as

 

auto record.

 

Record latch

System can delay the

record for specified time after a

detection event ended. The value ranges from 10s to 300s.

 

 

 

Email

If you enabled this function, the system can send out email to

136

Page 150
Image 150
Honeywell HD-DVR-1004, HD-DVR-1008, HD-DVR-1016 user manual 136