HP OpenView Storage B6960-96008 manual Testing Using the Data Protector CLI

Models: OpenView Storage B6960-96008

1 396
Download 396 pages 29.22 Kb
Page 218
Image 218

Integrating SAP R/3 and Data Protector

Configuring an SAP R/3 Backup

2.In the Scoping Pane, expand Backup, then Backup Specifications, SAP R/3, and right-click the backup specification you want to preview.

3.Click Preview Backup to open the Start Preview dialog box. Select the type of backup you want to run as well as the network load. See online Help for a description of these options.

Testing Using the Data Protector CLI

A test can be executed from the CLI on the SAP R/3 Database Server system or on any other Data Protector client within the same cell, provided that the systems have the Data Protector User Interface installed.

Run the omnib command with the -test_baroption as follows:

On HP-UX and Solaris: /opt/omni/bin/omnib -sap_list \ <backup_specification_name> -test_bar

On other UNIX: /usr/omni/bin/omnib -sap_list \ <backup_specification_name> -test_bar

On Windows: <Data_Protector_home>\bin\omnib -sap_list<backup_specification_name> -test_bar

What Happens? The session messages are displayed on the screen during the command execution, while the following happens:

The omnisap.exe program is started, which then starts the Data

Protector testbar command. This command then checks:

the communication within Data Protector,

the syntax of the SAP R/3 backup specification,

if the devices are correctly specified,

if the required media reside in the devices.

196

Chapter 2

Page 218
Image 218