HP OpenView Storage B6960-96008 manual Configuration Problems, 218

Models: OpenView Storage B6960-96008

1 396
Download 396 pages 29.22 Kb
Page 240
Image 240

Integrating SAP R/3 and Data Protector

Troubleshooting

b. If this fails, refer to the SAP R/3 Online Help to learn how to execute backup and restore directly to disk using the SAP R/3 backup utility.

Check the error message and resolve these problems before you continue.

4. Verify that the SAP R/3 backup tools correctly start backint (which is provided by Data Protector):

Move the original backint and create a test script named backint.bat in the directory where the SAP R/3 backup utility resides, with the following entries:

echo "Test backint called as follows:" echo "%0%1%2%3%4%5%6%7%8%9"

exit

Then start the following commands:

brbackup -t offline -d util_file -u <user>/<password> -c

 

If you receive backint arguments, this means that SAP R/3 is properly

 

configured for backup using backint; otherwise you have to reconfigure

 

SAP R/3.

 

See “Configuring an SAP R/3 Database Server” on page 167.

 

Configuration Problems

 

 

IMPORTANT

The procedure described in the previous sections must be performed

 

before you start checking the Data Protector configuration.

 

1. Verify that the Data Protector software has been installed

 

properly.

Refer to the HP OpenView Storage Data Protector Installation and

Licensing Guide for details.

218