HP manual Troubleshooting access to array-based HP P6000 Command View, Failed transceiver

Models: P6000

1 105
Download 105 pages 28.73 Kb
Page 67
Image 67

Failed transceiver

When a transceiver (or Gigabit Interface Converter (GBIC)) fails, the Disk Enclosure Properties window displays the following information:

On the Power tab, the operational state displays Good.

On the Cooling tab, the status of the sensors displays OK.

On the I/O-Comm tab, the operational state of the I/O modules displays Bad or Not Installed.

See the user guide for your controller to view the event log entries for this entity.

Failed I/O module

When an I/O module fails, the Disk Enclosure Properties window displays the following information:

On the Power tab, the operational state displays Good.

On the Cooling tab, the status of the sensors displays OK.

On the I/O-Comm tab, the operational state of the I/O modules displays Not Installed or Failed.

See the user guide for your controller to view the event log entries for this entity.

Failed blower power supply

When a blower power supply fails, the Disk Enclosure Properties window displays the following information:

On the Power tab, the operational state of a power supply displays Unknown.

On the Cooling tab, the operational state of a blower displays Unknown and the status of the power supply temperature sensor displays Not Available.

See the user guide for your controller to view the event log entries for this entity.

Troubleshooting access to array-based HP P6000 Command View

Problem

The logon to array-based HP P6000 Command View indicates Access Denied.

Explanation / Resolution

The HP P6000 Command View client filter in the HP P6000 Control Panel is enabled and access has been denied.

Troubleshooting access to array-based HP P6000 Command View 67

Page 67
Image 67
HP manual Troubleshooting access to array-based HP P6000 Command View, Failed transceiver, Failed I/O module