Failed transceiver
When a transceiver (or Gigabit Interface Converter (GBIC)) fails, the Disk Enclosure Properties window displays the following information:
•On the Power tab, the operational state displays Good.
•On the Cooling tab, the status of the sensors displays OK.
•On the
See the user guide for your controller to view the event log entries for this entity.
Failed I/O module
When an I/O module fails, the Disk Enclosure Properties window displays the following information:
•On the Power tab, the operational state displays Good.
•On the Cooling tab, the status of the sensors displays OK.
•On the
See the user guide for your controller to view the event log entries for this entity.
Failed blower power supply
When a blower power supply fails, the Disk Enclosure Properties window displays the following information:
•On the Power tab, the operational state of a power supply displays Unknown.
•On the Cooling tab, the operational state of a blower displays Unknown and the status of the power supply temperature sensor displays Not Available.
See the user guide for your controller to view the event log entries for this entity.
Troubleshooting access to array-based HP P6000 Command View
Problem
The logon to
Explanation / Resolution
The HP P6000 Command View client filter in the HP P6000 Control Panel is enabled and access has been denied.
Troubleshooting access to