Note

This information also appears in the MultiNet v4.4 Installation and Administrator Guide. For more details on configuring MultiNet, see the MultiNet documentation.

1.Start the configuration program with the following command:

$ MULTINET CONFIGURE /INTERFACE NET-CONFIG>

2.Enable the MultiNet UCX driver interface with the following command:

NET-CONFIG>SET LOAD-UCX-DRIVER TRUE

3.Exit the configuration program with the following command:

NET-CONFIG> EXIT

4.Edit your system startup command procedure to invoke MultiNet before starting DECwindows.

5.Reboot the system to start MultiNet with the UCX $QIO driver loaded.

1.6.4.4Continuous CPU Usage After Daylight Savings Time Change

On OpenVMS 7.3 and higher, when the time is moved forward or back for the Daylight Savings Time adjustment, multi threaded processes can go into a tight CPU loop. Applications subject to this behavior include DCPS symbiont, DECevent, and anything using the Java runtime such as the DESTA director. Stopping and restarting the processes (“desta stop” followed by “desta start”) corrects the problem.

To resolve this issue, install the patch VMS73_TDF–V0100 or VMS731_TDF–V0100. Otherwise, the behavior will happen again at each Daylight Savings Time adjustment.

1.6.4.5 New OpenVMS Patch Removal Feature

During WEBES installation, you may see messages similar to the following:

The following product has been selected:

Platform (product suite)

DEC AXPVMS WEBES V4.2-0

Information has been saved to allow you to uninstall the following patches:

RECOVERY DATA SET 001 created 25-JUL-2003 00:06:16.52

PATCH--------------------------------------

--------------------------

APPLIED TO

DEC--------------------------------------AXPVMS VMS731_LAN V6.0

--------------------------

DEC AXPVMS VMS V7.2-2

--------------------------------------

--------------------------

*If you continue, recovery data for the patches listed above will be deleted.

*The deletion of recovery data does not affect the installation status of

*patches applied to products that are not participating in this operation.

*However, continuing with this operation prevents you from uninstalling

*these patches at a future time by use of the PRODUCT UNDO PATCH command.

Page 32
Image 32
HP Web-Based Enterprise Services 4.5 manual Continuous CPU Usage After Daylight Savings Time Change