LEAD EDGE/TRAIL EDGESENSORS

MOTOR SPEED

EXPECTED LENGTH:

610

MEASURED LENGTH:

0

PRESS START TO ADJUST SPEED

Select the LEAD EDGE/TRAIL EDGE option to execute the lead edge/trail edge adjustment diagnostic.

To run the LEAD EDGE/TRAIL EDGE diagnostic:

1.Press the Menu key. The MAIN MENU screen is displayed.

2.Press the Next key until DIAGNOSTICS is highlighted.

3.Press the Enter key to select DIAGNOSTICS. The DIAGNOSTICS menu screen is displayed.

4.Press the Next key until SCANNER DIAGNOSTICS is displayed.

5.Press the Enter key to select SCANNER DIAGNOSTICS. The SCANNER DIAGNOSTICS menu screen is displayed.

6.Press the Next key until COMPONENT TESTS is highlighted.

7.Press the Enter key to select COMPONENT TESTS. The COMPONENTS TESTS menu screen is displayed.

8.Press the Enter key to select LEAD EDGE/TRAIL EDGE. The LEAD EDGE/TRAIL EDGE ADJUSTMENT screen is displayed.

LEAD EDGE/TRAIL EDGE

ADJUSTMENT

PRESS START TO BEGIN

9.Insert a black sheet (8.5 X 11) of paper into the Scanner.

10.Press the Start key to begin the diagnostic. When the diagnostic completes, the last line of the display is replaced with a status line indicating PASS or FAIL. The last line may also display as NO RESPONSE FROM SCANNER if the Scanner does not process the request within the timeout period.

11.Press the Enter key to return to the COMPONENT TESTS menu screen.

Select the SENSORS option to display the current state of the Scanner optical paper sensors, calibration home sensor, and the thick document sensor.

To display the status of the sensors: