CLEAR SCANNER FAULT LOG
CLEAN CAL ZONE
COMPONENT TESTS
The CLEAR SCANNER FAULT LOG option is for use by the Customer Service Engineer only and requires the entry of the diagnostic password. It allows the Customer Service Engineer to erase the contents of the Scanner Fault Log.
If you select this option, the CLEAR SCANNER FAULT LOG screen is displayed. You cannot perform any functions in this screen. Press the Exit key to return to the SCANNER DIAGNOSTICS menu screen.
Below is an illustration of the CLEAR SCANNER FAULT LOG screen.
CLEAR SCANNER FAULT LOGWARNING: THIS FUNCTION
DESTROYS ALL LOG MESSAGESEXECUTE: NO
The CLEAR CAL ZONE (Clear Calibration Zone) provides the user with a quick way to move the Calibration Motor to the cleaning position. There are two selections CLEANING POSITION AND HOME POSITION.
CLEAN CAL ZONEPOSITION: CLEANING POSITIONThe COMPONENT TESTS option of the SCANNER DIAGNOSTICS menu provides a
∙MOTOR SPEED - Enables the Customer Service Engineer to adjust the Scanner motor speed and correct magnification errors in the process direction. The diagnostic password is required for this function.
∙LEAD EDGE/TRAIL EDGE - Enables you to execute the lead edge/trail edge diagnostic.
∙SENSORS - Enables you to display the current state of the Scanner optical paper sensors and the thick document sensor.
∙MOTOR COMMUNICATIONS - Enables a document motor communications loopback test to assist in diagnosing a scanner problem.
∙DOCUMENT MOTOR - Enables you to stop and start the document handler motor.
124 ∙Main Menu | XEROX WIDE FORMAT COPY SYSTEM |