IBM CDI5UG1107 manual PCLASSn, Phold*Yes*No*Call, PNOTIFYuserid, Ppacctpnode accounting-data

Models: CDI5UG1107

1 178
Download 178 pages 15.27 Kb
Page 104
Image 104

104IBM Sterling Connect:Direct for i5/OS User’s Guide

PCLASS(n)

specifies the Sterling Connect:Direct Process CLASS for the submitted remote Process. This entry overrides the class specified in the Process.

PHOLD(*YES*NO*CALL)

specifies whether the submitted remote Process is placed in the hold queue at submission. The default is the HOLD value of the Process.

*YES specifies that the Process submits to the hold queue.

*NO specifies that the Process executes as soon as possible.

*CALL specifies that the remote Process is placed in the hold queue until a session is established with its SNODE.

PLEXCLASS(user-defined class)

specifies a user-defined class containing up to eight characters associated with a Sterling Connect:Direct/Server in a Sterling Connect:Direct/Plex environment. This represents a type of server on which you want to submit a Sterling Connect:Direct Process.

Note: This parameter is for use only in Sterling Connect:Direct for z/OS environments.

PNAME(process-name)

identifies the Process in any messages or statistics. The name is from 1 to 12 characters long. The first character must be alphabetic. The default name is CDSND.

Note: Only Sterling Connect:Direct for i5/OS and Sterling Connect:Direct for UNIX support Process names with more than 8 characters.

PNODEID(id, pswd, newpswd)

specifies security user IDs and passwords at the local node. Use this parameter only to validate security with a different ID than the one you used to sign on to Sterling Connect:Direct. Do not use PNODEID when both the ID and password match on the local and remote nodes.

id specifies the security ID passed to the security system at the local node (1–10 alphanumeric characters).

pswd specifies the current security password for the specified ID. The security system at the local node can use this parameter to validate the current security password (1–10 alphanumeric characters). This is optional unless the user has security set to require a password.

newpswd specifies the new security password.

Note: Although you can specify a value for newpswd, Sterling Connect:Direct for i5/OS does not support this parameter.

PNOTIFY(userid)

specifies the user who is to receive remote Process completion messages. This entry overrides the one specified in the Process.

PPACCT(PNODE accounting-data)

specifies the accounting data for the PNODE in the submitted remote Process. This entry overrides the one specified in the Process.

Page 104
Image 104
IBM CDI5UG1107 manual PCLASSn, Phold*Yes*No*Call, PNOTIFYuserid, Ppacctpnode accounting-data