IBM CDI5UG1107 manual Trace Instructions

Models: CDI5UG1107

1 178
Download 178 pages 15.27 Kb
Page 97
Image 97

Running a Remote Task

97

pswd specifies the current security password for the specified ID. The security system at the local node can use this parameter to validate the current security password (1–10 alphanumeric characters). This is optional unless the user has security set to require a password.

newpswd specifies the new security password. The security system can use this parameter to change the current security password to the new security password (1–10 alphanumeric characters).

Note: Although you can specify a value for the new password, Sterling Connect:Direct for i5/OS does not currently support this parameter.

RMTWORK(*YES*NO)

specifies whether a remote Process can run on the session after Sterling Connect:Direct for i5/OS has completed its Process on the session.

*YES allows a remote Process to run on the session after the Sterling Connect:Direct for i5/OS completes its Process.

*NO terminates the session after Sterling Connect:Direct for i5/OS executes the command function. *NO is the default.

SACCT(snode-accounting-data)

specifies the accounting data for the remote node. The maximum length of the accounting data is 256 characters. If special characters are part of the accounting data, the string must be enclosed in single quotation marks.

SNODEID(id, pswd, newpswd)

specifies security user IDs and passwords at the remote node. This parameter should only be used to validate security with a different ID than the one you used to sign on to Sterling Connect:Direct.

id specifies the security ID passed to the security system on the remote node (1–64 alphanumeric characters).

pswd specifies the current security password and is used by the security system on the SNODE to validate the current security password (1–64 alphanumeric characters). This parameter is optional unless the user has security set to require a password.

newpswd specifies the new security password and is used by the security system to change the current security password to the new security password (1–64 alphanumeric characters).

Note: newpswd is not valid if the remote node is a Sterling Connect:Direct for i5/OS node. Parameter values are case sensitive.

TRACEOPT

Trace Instructions

(L, S, F, C, X, K, D, H, V, W, P,*NONE*ALL*EXT *COMMON*INITPARMS*CURRENT

specifies the trace bits that define functions to be traced by Sterling Connect:Direct for i5/OS. The following are valid options:

™L enables the main line logic trace for all components.

™S enables the Process step logic trace.

™F enables the file handler trace.

™C enables the communications logic trace.

™X enables the XDR trace.

™K enables the KQV logic trace.

™D enables the all-purpose data dump.

Page 97
Image 97
IBM CDI5UG1107 manual Trace Instructions