Controlling Processes

127

™*ALL enables all product traces.(L, S, F, C, X, K, D, H, V, and P)

™*EXT enables all product traces plus two other traces. (TRCICF and TRCJOB)

™*COMMON enables the most commonly used traces. (L, S, F, C, and H)

™*NONE turns off all traces.

Using the CDSUBPROC Screens

Use the Connect:Direct Submit Process (CDSUBPROC) screen to submit a Sterling Connect:Direct Process to the Process queue for asynchronous execution.

Submitting a Process for Asynchronous Execution

Complete the following steps to submit a Process to the Process queue for asynchronous execution:

1.Access the CDSUBPROC screen by typing CDSUBPROC at the command line and pressing F4 or by choosing the submit process option from the Sterling Connect:Direct menu.

2.Enter the parameters that define the Process execution: CMD, STARTT, RETAIN, HOLD, and

PRIORITY.

3.After you enter the command, press F4 to display the applicable entry fields for the command.

4.After you complete the parameters for the CDSUBPROC command, press Enter. Your Process name and number are assigned and displayed. The Process is placed in the Process Management Queue.

The following screen is an example of the Connect:Direct Submit Process screen.

Submit C:D Process (CDSUBPROC)

Type choices, press Enter.

Connect:Direct command . . . . . CMD______________________________________________

____________________________________________________________________________________

____________________________________________________________________________________

____________________________________________________________________________________

____________________________________________________________________________________

____________________________________________________________________________________

__________________________________________________________________

...

Execution date & time:

 

*NONE___

Character value, *SUN...

 

Start

date

 

Start

time

*NONE___

Character value, *NONE...

 

Frequency

*NONE___

*NONE, *DAY, *WEEK

 

Retain process after execution

*NO_____

*NO, *YES, *INITIAL

 

Hold process on queue

*NO

*NO, *YES

 

 

Priority on queue

7______

1-15

 

 

F3=Exit

F4=Prompt

F5=Refresh

F10=Additional parameters

Bottom

 

F12=Cancel

 

F13=How

to use this display

F24=More keys

 

 

 

Page 127
Image 127
IBM CDI5UG1107 manual Using the Cdsubproc Screens, Submitting a Process for Asynchronous Execution