NEW specifies that the operation creates the destination member for an existing file. NEW is the default. The file is created if the member does not exist. The file cannot be created if the member already exists.

OLD specifies that the destination member already exists. The operation has exclusive control of the member.

MOD specifies that the operation modifies the member by adding data to the end of the member or, if none exists, allocates a new member. The file is also created if it does not exist.

RPL specifies that the destination member replaces any existing member or, if none exists, allocates a new member. The file is created if it does not exist.

SHR specifies that the destination member already exists. The file is read simultaneously by another job or operation.

Note: Normal and abnormal second disposition are not applicable when sending to Sterling Connect:Direct for i5/OS.

For information on parameters for other platforms, refer to the appropriate volume of the IBM Sterling Connect:Direct Processes Web site at http://www.sterlingcommerce.com/documentation/processes/processhome.html.

TIOEXIT(program-name)

specifies the name of the user-written program to be given control for I/O-related requests for the associated data. This parameter is valid for z/OS nodes only.

TIOPARM(parameter-name)

establishes a parameter, or list of parameters, to be passed to the specified exit. The TIOPARM syntax is dependent on the parameter list required by the program specified in TIOEXIT. This parameter is valid for z/OS nodes only.

TLABEL(seqno,labeltype,pswdread,inout,retpd,expdt)

specifies label information for the tape. This parameter is valid for z/OS nodes only.

seqno specifies the relative file position on the tape.

labeltype is designated as:

SL specifies IBM standard labels.

AL specifies American National Standard labels. BLP specifies bypass label processing.

LTM specifies bypass leading tape marks. NL specifies no labels.

pswdread specifies that a password must be given by the operator or user before the file is accessed.

inout specifies that a BSAM data set opened for INOUT or a BDAM data set opened for UPDAT is to be read only.

retpd specifies the retention period for the data set in days, where nnnn is 1–4 digits.

expdt specifies the expiration date for the data set, where yyddd or yyyyddd is a valid Julian date.