Receiving a File

59

trtch specifies the magnetic tape mode setting. When coded together, Sterling Connect:Direct for z/OS uses the TRTCH and DEN values to select a tape device for allocation. Valid options are:

C specifies data conversion, odd parity, and no translation.

E specifies no data conversion, even parity, and no translation.

T specifies no data conversion, odd parity, and BCD or EBCDIC translation. ET specifies no data conversion, even parity, and BCD or EBCDIC translation.

COMP is a feature for 3480X tape drives only. It enables Improved Data Recording Capability (IDRC), which compresses the data. This subparameter overrides the system-wide IDRC setting for no compression. If you are specifying COMP, you must also include a UNIT= parameter that specifies either 3480X or a systems programmer-defined name equivalent to a 3480X tape drive.

NOCOMP overrides the system-wide IDRC setting for compression. NOCOMP applies to 3480X tape drives only.

FDISP(current, normal end, abnormal end)

specifies the status of the remote file and what is to be done with the file after notification of successful transmission.

current specifies the status of the file. Valid values are:

SHR specifies that the file can be read simultaneously by another operation. SHR is the default. OLD specifies that the operation is to be given exclusive control of the file.

normal end specifies the disposition of the file following normal operation termination. Valid dispositions are as follows:

KEEP specifies that the system is to keep the file after the operation completes. DELETE specifies that the system is to delete the file after the operation completes.

abnormal end specifies the disposition of the file after abnormal operation termination. Valid source file dispositions are:

KEEP specifies that the system is to keep the file after the operation terminates abnormally. DELETE specifies the system is to delete the file if the operation terminates abnormally.

For subparameters for other Sterling Connect:Direct platforms, refer to the IBM Sterling Connect:Direct Processes Web site at

http://www.sterlingcommerce.com/documentation/processes/processhome.html.

Note: Currently, normal end disposition and abnormal end disposition are not applicable for Sterling Connect:Direct for i5/OS.

FIOEXIT(program-name)

specifies the name of the user-written program to be given control for I/O-related requests for the associated data.

FIOPARM(parameter-name)

specifies a parameter, or list of parameters, to be passed to the specified exit. This parameter is valid only when the source side is a z/OS node. The FIOPARM syntax depends on the parameter list that the program specified in FIOEXIT requires.

FLABEL(seqno, labeltype, pswdread, inout, retpdexpdt) specifies label information for the tape.

seqno specifies the relative file position on the tape.

Page 59
Image 59
IBM CDI5UG1107 manual FDISPcurrent, normal end, abnormal end, FIOEXITprogram-name, FIOPARMparameter-name