84IBM Sterling Connect:Direct for i5/OS User’s Guide

PNODEID(id, pswd, newpswd)

specifies security user IDs and passwords at the local node. This parameter should only be used to validate security with a different ID than the one you used to sign on to Sterling Connect:Direct. PNODEID is not used when both the ID and password match on the local and remote nodes.

id specifies the security ID passed to the security system on the local node (1–10 alphanumeric characters).

pswd specifies the current security password for the specified ID. This parameter is used by the security system on the local node to validate the current security password (1–10 alphanumeric characters). This is optional unless the user has security set to require a password.

newpswd specifies the new security password. It is used by the security system to change the current security password to the new security password (1–10 alphanumeric characters).

Note: Although you can specify a value for newpswd, Sterling Connect:Direct for i5/OS does not support this parameter.

PRTY(n)

specifies the priority of the operation. High numbers indicate high priorities; low numbers indicate low priorities. Use this priority only for selection within CLASS. It does not affect transmission priority. The range is from 0–15. The default is *INITPARMS. Type DSPPFM INITPARMS to view the default.

RMTWORK(*YES*NO)

specifies whether a remote Process can run on the session after Sterling Connect:Direct for i5/OS has completed its Process on the session.

*YES allows the remote Process to run on the session after Sterling Connect:Direct for i5/OS completes its Process.

*NO terminates the session after Sterling Connect:Direct for i5/OS executes the command function. *NO is the default for this parameter.

SACCT(snode-accounting-data)

specifies the accounting data for the remote node. The maximum length of the accounting data is 256 characters. If special characters are part of the accounting data, the string must be enclosed in single quotation marks. This parameter is valid for z/OS nodes only.

SECOPTIONS(* *)

specifies Encryption and Digital Signature values.

Encryption specifies if data encryption is to be performed and what algorithm to use.

Digital Signature specifies if a digital signature is created during file transmission.

Note: The SECOPTIONS parameter is valid only if Sterling Connect:Direct Secure Plus is installed. For information about these parameters, refer to the IBM Sterling Connect:Direct Secure Plus for i5/OS Implementation Guide.

SNODEID(id, pswd, newpswd)

specifies security user IDs and passwords at the remote node. Use this parameter only to validate security with a different ID than the one you used to sign on to Sterling Connect:Direct.

Note: Parameter values are case sensitive.

Page 84
Image 84
IBM CDI5UG1107 manual PNODEIDid, pswd, newpswd, PRTYn