SRN

FRU

List

 

 

Problem

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49700

None

 

 

 

Description:

The

parity

for

the

array

is

not

 

 

complete.

 

 

 

 

 

 

 

 

Action: Go to “MAP 2010: START”

on

page 2010-1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50000

SSA

adapter

card

(100%)

Description:

The

SSA

adapter

failed

to

respond

 

 

to

the

device

 

 

 

 

 

driver.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50001

SSA

adapter

card

(100%)

Description: A data parity error

has

occurred.

 

 

 

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50002

SSA

adapter

card

(100%)

Description: An SSA adapter DMA

error

has

occurred.

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50004

SSA

adapter

card

(100%)

Description:

Channel

check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50005

SSA

adapter

card

(100%)

Description:

A software

error

has

occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Go to “Software and Microcode

 

Errors”

on

 

 

page 12

 

 

 

 

 

 

 

before

exchanging

the

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50006

SSA

adapter

card

(100%)

Description: A channel check has

occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50008

SSA

adapter

card

(100%)

Description:

Unable

to

read

or

write

the

PCI

 

registers.

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50010

SSA

adapter

card

(100%)

Description: An SSA adapter or

device

 

drive

protocol

error

has

 

 

 

 

 

occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Go to “Software and Microcode

 

Errors”

on

 

 

page 12

 

 

 

 

 

 

 

before

exchanging

the

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50012

SSA

adapter

card

(100%)

Description:

The

SSA

adapter

microcode

 

has

hung.

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Run nonconcurrent diagnostics to

the

SSA

adapter.

 

 

 

 

 

 

 

 

If

the

diagnostics

fail,

exchange

the

FRU for

 

a

new

FRU.

 

 

 

 

 

If the diagnostics do not

fail, go to “Software and Microcode

 

 

 

 

 

Errors” on page 12 before exchanging

 

the

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D4000

SSA

adapter

card

(100%)

Description:

The

diagnostics

cannot

configure

the

 

SSA

adapter.

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D4100

SSA

adapter

card

(100%)

Description:

The

diagnostics

cannot

open

the

SSA

 

adapter.

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D4300

SSA

adapter

card

(100%)

Description:

The

diagnostics

have

detected

an

 

SSA

 

adapter

 

 

 

 

 

 

 

POST

failure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Exchange the FRU for

a

new

 

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFFFF

SSA

adapter

card

(100%)

Note:

The

 

description

and

action

for

 

this

SRN

are

valid

only

if

 

 

 

 

 

you

have

run

diagnostics

to

the

SSA

attachment.

 

If

this

SRN

 

 

 

 

 

 

has occurred because you have run diagnostics on some other

 

 

 

 

 

device,

see

the

service

information

 

for

that

 

device. Description:

 

 

 

 

 

A command or parameter that

has been sent or received is not

 

 

 

 

 

valid. This

problem

is

caused

either

 

by

the

SSA

 

adapter,

or

by

 

 

 

 

 

an error in the microcode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action: Go to “Software and Microcode

 

Errors”

on

 

 

page 12

 

 

 

 

 

 

 

before

exchanging

the

FRU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service Request Numbers (SRNs)11

Page 19
Image 19
IBM SY33-0193-00 manual Service Request Numbers SRNs11