MAP 2324 (continued)
033 (continued)
Run nonconcurrent diagnostics to all the disk drives that are listed as rejected.
Run the Certify service aid (see “Certify Disk” on page 35) to all the disk drives that
are listed as rejected.
If problems occur on any disk drive go to Step 034, otherwise, continue with this
procedure.
Do the actions described in “Adding a Disk Drive to an Array” on page 44.
Referring to the displayed instructions, select a disk from the list of array candidate
disk drives, and add that disk drive to the array that is in the Degraded state. The
array changes its state to the Good state, and parity is rebuilt.
034
(From step 033)
Exchange the disk drive for a new one (see “Exchanging Disk Drives” on page 19).
Go to Step 090 on page 2324-18 to add the disk drives to the group of disk drives that
are available for use by the RAID manager.
Note: A disk drive that is listed as rejected is not necessarily failing. For example, the
array might have rejected the disk drive because a power problem, or an SSA link
problem, caused that drive to become temporarily unavailable. Under such conditions,
the disk drive can be reused.
035
(From step 032)
DOES THE DISK SERVICE AID INDICATE AN OPEN LOOP?
Yes No
036
Go to Step 038.
037
Go to “MAP 2320: SSA Link” on page 2320-1.
038
(From steps 036 and 046)
(Step 038 continues)
2324-8 IBM SerialRAID Adapter Maintenance Information