MAP 2324 (continued)

013(continued)

The status

of

the array changes to Good when the adapter can find all the member

drives of

the

array.

 

 

 

 

014

(From step 012)

Either more than one disk drive has failed, or an array that is not complete has be connected to the IBM SerialRAID Adapter.

If no disk drives have been added to this system, go to Step 015.

If one or more disk drives have been added to this system, and those disk drives previously members of an array on this system or on another system, you must do the following:

– Do the

actions that are described in “Deleting a Resource from the System Resource

List” on

page 43.

– Select the array that is in the Offline state, and delete it.

That array is now a free resource.

– Do the

actions that

are

described in

“Removing a

Disk Drive from an Array” on

page 43,

and remove

all

the disk drives

from the

array.

You can now use those disk drives as free resources.

Locate and repair all failed disk drives, and make those disk drives available for t creation of a new array.

Go to Step 015.

015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(From

step

014)

 

 

 

 

– Using

the

DOS

Configurator

select

the

appropriate adapter, then from the adapter

menu

 

selectRejected

Disks .

 

 

 

– Using

the

RSM

configurator,

go to

the

Logical RejectedView .and select

ARE ANY

DISK DRIVES LISTED?

 

 

 

Yes

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– Ask the user to delete and recreate the array that is in the Offline state.

017

– Run nonconcurrent diagnostics to all the disk drives that are listed as rejected. (Step 017 continues)

2324-4IBM SerialRAID Adapter Maintenance Information

Page 76
Image 76
IBM SY33-0193-00 manual Disks, Are ANY Disk Drives LISTED?