057 (continued)
DOES ANY ARRAY HAVE ONE OR MORE UNBUILT PARITY STRIDES, OR ONE
OR MORE UNBUILT COMPONENT STRIDES?
Yes No
058
The error might have occurred because a hot spare drive was being started and
rebuilt.
Check whether any failed disk drives are present in the array.
059
Note the array name of the failing array.
Go to Step 060.
060
(From step 059)
Using the DOS Configurator, open the adapter list and select the appropriate
adapter.
select System Resources from the adapter menu.
Select the failing array.
Select View Members.
Using the RSM configurator, just selecting the array shows all members
Select the failing disk drive.
Note all the Resource Nnumbers that are in the array.
Ask the user to create a backup of all the data that is contained in this array. (All the
data should be accessible without error.)
Ask the user to delete the array.
Run nonconcurrent diagnostics to each of the disk drives that you noted previously.
DO THE DIAGNOSTICS FAIL WHEN RUN TO ANY PARTICULAR DISK DRIVE?
Yes No
061
Go to Step 063 on page 2324-14.
062
(Step 062 continues)