MAP 2324 (continued)

043(continued)

– Run

the Certify

service aid (see “Certify Disk” on page 35) to all the disk drives

are

listed as

rejected.

If problems occur on any disk drive go to Step 044, otherwise continue with this procedure.

– Do the actions described in “Adding a Disk Drive to an Array” on page 44.

– Referring

to

the

displayed

instructions, select a disk from

the

list

of array candi

disk drives,

and

add

that

disk

drive

to the

array

that

is

in

the

Exposed state.

The

array

changes

its

state

from

the

Exposed

state,

and

parity

is rebuilt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

044

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(From

step

043)

 

 

 

 

 

 

 

 

 

 

 

 

 

– Exchange the disk drive for a new drive (see “Exchanging Disk Drives” on page 19).

Go

to

Step

090

on

page 2324-18

to

add the disk

drives to

the group of

disk drives t

are

 

available

for

use

by

the RAID

manager.

 

 

 

 

Note:

 

A

disk

drive

that

is

listed

as

rejected

is not necessarily defective. For examp

the

 

array might have rejected the disk drive

because a power problem or an SSA link

problem

caused

that

drive

to

become

temporarily

unavailable.

Under such

conditions

the

 

disk

drive

can

be

reused.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

045

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(From step

 

042)

 

 

 

 

 

 

 

 

 

 

 

 

DOES

THE

DISK

SERVICE

AID

INDICATE

AN

OPEN

LOOP?

 

 

 

 

 

 

Yes

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

046

Go to Step 038 on page 2324-8.

047

Go to “MAP 2320: SSA Link” on page 2320-1.

048

(From step 003)

No spare disk drives are available for an array that is configured for hot-spare dis drives.

– If the subsystem contains disk drives that have failed, repair those disk drives, exchange them for new disk drives (see “Exchanging Disk Drives” on page 19).

(Step 048 continues)

2324-10IBM SerialRAID Adapter Maintenance Information

Page 82
Image 82
IBM SY33-0193-00 manual Yes 046, 047, 048