MAP 2410: SSA Repair Verification

This

 

MAP

helps you to verify a repair

after

a

FRU

has

been

exchanged

for a

new

Attention:

Unless the system unit needs

to

be

turned

off

fordo

some other

reason,

 

not

turn

off the system when servicing

an SSA link or a unit in

which SSA

devices

are

installed. Unit power cables and external SSA cables

that connect

devices

to

the

 

system

can

be

disconnected while that

system

is

running.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Before

you arrived at this MAP, you

might

have

exchanged

one

or more FRUs for ne

FRUs. Some

of

those FRUs (for example, disk

drives)

have

Power lights.

 

 

 

– Check whether all those Power lights are on.

DO ALL

THE FRUS YOU HAVE EXCHANGED HAVE THEIR POWER LIGHTS ON

(WHERE

APPLICABLE)?

Yes

No

 

 

 

 

 

 

 

 

 

 

002

 

 

 

 

 

– Exchange, for a new one, the FRU whose Power light is off.

Go to Step 004.

003

Go to Step 004.

004

(From steps 002 and 003)

ARE ALL CHECK LIGHTS OFF?

Yes No

005

Go to the START MAP for the unit in which the device with its Check light on i installed.

006

Run concurrent diagnostics to the device that reported the problem.

Notes:

1.Do not run nonconcurrent diagnostics; otherwise, errors are logged on other systems that share the same loop.

(Step 006 continues)

MAPs 2410-1

Page 93
Image 93