Ingersoll-Rand 4575759 user manual Setting Torque Units

Models: 4575759

1 116
Download 116 pages 13.37 Kb
Page 38
Image 38

Sensor I® Expert User Manual

At the top right-hand section of the screen is the cycle count indicator. It displays the number of completed tightenings for that mode (up to 999 tightenings). The counter increments by one at the end of each tightening once the Reset button has been pressed.

For the most accurate results, the wrench should be pulled at a speed between 10 and 80 degrees per second. The wrench should be held steady while the Reset button is pressed.

Setting Torque Units

The units of displayed torque can be toggled between Metric and English units by pressing the Units key on the front panel. The current units selected are indicated in the center right-hand section of the screen.

The wrench can also display torque in units of different sizes. The following procedure toggles the wrench units between Nm (or lb.ft.) and dNm (or in.lb.).

1.Press the Reset button to power up the wrench.

2.Move the Mode Selection switch to Setup.

3.With the Reset button held in, use the Parameter Adjustment Knob to select the Custom Setup Mode #107. The main display shows "---", and the torque units are displayed in the center right-hand section of the screen.

4.Hold the Reset button and press the Units button to choose units of Nm and lb.ft. Press the Joint button to choose units of dNm and in.lb.

5.Press and hold the Reset button and rotate the Parameter Adjustment Knob counterclockwise until the Custom Setup Mode number is below 20.

16

Page 38
Image 38
Ingersoll-Rand 4575759 user manual Setting Torque Units