Sensor I® Expert User Manual

8.Holding in the Reset button, adjust the Custom Setup Mode number below 20.

9.Release the Reset button and move the Mode Selection switch to the desired tightening mode.

Parameter Dump

Once initiated the parameter dump function will dump out settings for a particular tightening mode. A parameter dump can be performed on any primary or custom tightening mode. It is recommended that once custom modes have been setup that a parameter dump be initiated so there is a permanent record of the wrench's settings. This is not necessary if the wrench was programmed via the InterLink software.

NOTE

Tightening parameters of torque that are downloaded and uploaded in units of Nm or lb.ft. are rounded to the nearest Nm or lb.ft. If higher resolution or greater precision is required in the parameters that are transmitted, use units of dNm or in.lb. Actual data points transmit with a resolution of 1/10th of the units.

1.Connect the serial cable from the charger/data port to the serial port of the computer.

2.Press the Reset button to power up the wrench.

3.Move the Mode Selection switch to Setup.

4.With the Reset button held in, use the Parameter Adjustment Knob to select Custom Setup Mode #109. Note that an "A" appears on the main display.

5.Move the Mode Selection switch to Torque Control.

36

Page 58
Image 58
Ingersoll-Rand 4575759 user manual Parameter Dump