Ingersoll-Rand 4575759 user manual Tightening Curve Storage

Models: 4575759

1 116
Download 116 pages 13.37 Kb
Page 60
Image 60

Sensor I® Expert User Manual

5.Move the mode selection switch to Torque Control.

6.With the Reset button held in, use the Parameter Adjustment Knob to select the tightening mode for which the end of tightening data is to be transmitted over the serial interface. Select from:

A-

Angle Control

J-

Yield (joint) Control

b-

Dynamic Audit

t-

Torque Control

1 through 20-

Custom tightening modes 1-20

7.Release the Reset button once the tightening mode has been selected.

8.Press the Joint button and the tightening parameters, end of tightening data and statistics will be transmitted.

9.Move the Mode Selection switch to Setup.

10.Press in the Reset button and adjust the Custom Setup Mode # below 20.

Tightening Curve Storage

Up to 10 tightening curves can be stored in the Sensor I® Expert Wrench for later retrieval via the serial port. Tightening curves can be stored provided the following conditions have not occurred: wrench has powered down, has been switched to another tightening mode or another tightening has commenced.

The following procedure shows how to store a tightening curve.

38

Page 60
Image 60
Ingersoll-Rand 4575759 user manual Tightening Curve Storage