Ingersoll-Rand 4575759 user manual

Models: 4575759

1 116
Download 116 pages 13.37 Kb
Page 85
Image 85

Sensor I® Expert User Manual

on a flat surface, selecting Angle Control and pressing the Reset button until the front panel's FAULT light is extinguished and the green RUN light appears. Then proceed as follows:

NOTE

If this calibration procedure takes longer than 10 minutes or the wrench ambient temperature changes more than 5° Celsius, step 1 should be repeated.

2.Hold in the Reset button and select Custom Setup Mode #120. The wrench display will read "0.0°".

3.Rotate the Mode Select switch to the Dynamic Audit position.

4.Press the Reset button and Window key simultaneously. A CAL legend should appear on the wrench display. Calibration is now enabled. Release Reset.

5.Set the external monitoring equipment's snug torque to match the Torque Control Mode default snug torque of the wrench. The default snug values for all models are listed in the TOOL DESCRIPTION Technical Data table in Chapter 2.

6.Apply more than the snug torque to the wrench and rotate it through a known angle at a rate of between 20 and 45 degrees/second (do NOT ratchet the wrench). The wrench's displayed angle value will be the same as that shown on the external monitoring equipment6 (±2°). If not, turn the wrench's Parameter Adjustment Knob until they match.

7.Press the Reset button, and repeat step 6 to verify calibration.

8.Press the Display key to exit calibration.

9.Select Setup, hold in Reset and adjust the Mode below 20 to save.

57

Page 85
Image 85
Ingersoll-Rand 4575759 user manual