Ingersoll-Rand 4575759 user manual Data Out During Tightening

Models: 4575759

1 116
Download 116 pages 13.37 Kb
Page 56
Image 56

Sensor I® Expert User Manual

7.Press in the Reset button and adjust the baud rate to the desired value (valid baud rates are 19200, 9600, 4800, 2400, 1200 & 600).

NOTE

The last two numerals are not shown on the wrench display.

8.Move the Mode Selection switch to Setup.

9.Press in the Reset button and adjust the Custom Setup Mode number below 20.

10.Release the Reset button and move the Mode Selection switch to the desired tightening mode.

Data Out During Tightening

Once this function is activated, a torque data point will be transmitted via the serial port for every degree increment of the tightening angle beyond snug.

1.Connect the serial cable from the charger/data port to the serial port of the computer.

2.Press the Reset button to turn on the wrench.

3.Move the Mode Selection switch to Setup.

4.With the Reset button held in, use the Parameter Adjustment Knob to select Custom Setup Mode #101. Note: A symbol "RX" appears on the left-hand side of the digital display and the main display shows "--.-".

5.Rotate the mode select switch to the tightening mode for which the option is to be enabled. The display will show "OFF".

34

Page 56
Image 56
Ingersoll-Rand 4575759 user manual Data Out During Tightening, Last two numerals are not shown on the wrench display