Sensor I® Expert User Manual

7. Audible Alarm

Signals the completion of a tightening procedure by continuous tone and signals a fault by an intermittent tone. The audible alarm will only sound while torque is being applied to the wrench handle.

8. Charger/Data Port

The battery charger inserts into this connector to charge the wrench. The serial port cable provided with the wrench also plugs into this connector. This port is located in the end of the handle for models 125, 250 and 400. For model 40, it is located on the rear of the Control Unit.

9. Toggle Lever

Selects the direction of the ratcheting mechanism; markings "ON" and "OFF" apply to right-hand threaded fasteners.

10. Power Switch

Located under the cap on the back of the wrench body (models 125, 250 and 400 not shown) or Control Unit (model 40), this switch turns power on and off to the wrench.

11. Angle Reference Arm Connector (EA-models)

Provides a fixed reference for angel measurement while operating the wrench. It is attached to the work piece by a magnet base and spring arm.

12

Page 32
Image 32
Ingersoll-Rand 4575759 user manual Audible Alarm