Sensor I® Expert User Manual
8.Press and hold in the Reset button. The snug torque will be displayed.
9.With the Reset button held in, use the Parameter Adjustment Knob to adjust the snug torque to the desired value (approx. 50% of expected torque).
10.Release the Reset button. If the FAULT light is lit, then press and hold the Reset button again while holding the wrench steady. Continue to hold in the Reset but- ton until the RUN light appears and the FAULT light goes off. Release Reset.
11.Commence tightening with a steady pull at moderate speed. Stop as soon as the OK light comes on and the alarm sounds.
12.When audit is complete, press the Display key until "Tq" appears in the lower
13.Press the Display key until "Pk" appears in the lower