Ingersoll-Rand 4575759 user manual Quality Control Limits and Statistics

Models: 4575759

1 116
Download 116 pages 13.37 Kb
Page 48
Image 48

Sensor I® Expert User Manual

QUALITY CONTROL LIMITS AND STATISTICS

Setup and Viewing Quality Control Limits

1.Press and release the Reset button on the side of the wrench.

2.Move the Mode Selection switch to the tightening mode required.

3.Press the Window key. You will see "--.-" on the display along with "LT" (low torque limit) flashing in the top left hand corner.

4.Press and hold in the Reset button. The present low torque limit will be shown.

5.While holding in the Reset button, use the Parameter Adjustment Knob to adjust the low torque limit to the desired value. Release the Reset button and press the Window key.

6.To adjust the high torque limit (HT), low angle and high angle limits, (LA, HA), press the Window key until the desired limit is flashing. Then hold in the Reset button and adjust as in step 5 above.

7.When all adjustments have been made, press the Window key until all indicators (LT, HT, LA, HA) have stopped flashing on the display.

8.Press the Reset button until the RUN light appears and commence tight- ening.

NOTE

In Yield Control, LA and HA must be greater than or equal to 12° for hard joints, 16° for normal joints, or 24° for soft joints. LT and HT limits must be greater than the snug torque for all modes.