Sensor I® Expert User Manual

Exceptions for angle low and high limits:

NOTE

While in Angle Control:

To delete high and low angle settings, HA and LA must be adjusted to the target angle.

To delete high and low torque settings, HT and LT must be adjusted to the snug torque.

Use of Quality Control Limits

1.After the Reset button is pressed any limits that have been set will be indicated on the display with the corresponding segments lit (LT, HT, LA, HA).

2.Once snug torque is reached, the torque/angle lower limit indicators (LT, LA) will flash on the screen until their respective values are reached.

3.Once the lower limit values are reached, the indicators LT, LA will become solid.

4.If a high limit is exceeded HT or HA will begin flashing.

5.All limits that have been set will be indicated on the display with the corresponding segments lit (LT, HT, LA, HA).