Integra DTR-7.4 Configuring the 12V Trigger Terminal, When the “Basic Menu” is displayed, select

Models: DTR-7.4

1 104
Download 104 pages 42.07 Kb
Page 71
Image 71
Configuring the 12V Trigger Terminal

Using an External Device with 12V Trigger Terminal

Connecting to an External Device with 12V TRIGGER Terminal

DTR-7.4

A

ZONE 2

 

12V

 

TRIGGER OUT

B

12V TRIGGER

Device A

12V TRIGGER

Device B

12V TRIGGER

The device located in the Zone 2

These outputs can be connected to the 12-volt trigger inputs on other components. They output 12 volts (100 milliamperes max). The ZONE 2 TRIGGER OUT out- puts 12 volts while the DTR-7.4 is in Zone 2 mode. The A and B outputs can be assigned to input sources, in which case, the assigned trigger output outputs 12 volts while the input source is selected.

Configuring the 12V Trigger Terminal

1

Press the Input button, and then roll the

 

scroll wheel to select the input source you

 

want to set.

 

 

 

2

Press the scroll wheel, and then press the

 

Setup button.

 

 

When the “Basic Menu” is displayed, select

 

Advanced Menu” using the and cursor

 

buttons and press the Enter button to display the

 

“Advanced Menu.”

 

 

 

 

 

3

Use the

and

cursor buttons to select

 

“2. Input Setup” and then press the Enter

 

button.

 

 

 

The “Input Setup” menu appears.

 

 

 

 

4

Use the

and

cursor buttons to select

“12V Trigger” and then press the Enter button.

The “12V Trigger” menu appears.

5 Use the When the “Basic Menu” is displayed, select and cursor buttons to select an item and then use the “→Advanced Menu” using the and cursor and buttons and press the Enter button to display the cursor buttons to set the desired setting.

2-7.12V Trigger Setup

“Advanced Menu.”Input:DVD a. Trigger A

a.Trigger

A

:On

b.Trigger

B

:Off

 

 

Quit:SETUP

This sub-menu allows you to make the required settings to turn on the output from the 12V TRIGGER terminal to control another compo- nent or device with the DTR-7.4 for each input source.

a. Trigger A

On: Select to activate the device connected to the 12V TRIGGER A terminal when the input source is selected.

Off: Select when no device is connected to the 12V TRIGGER A terminal or you do not want the connected device to activate.

b. Trigger B

On: Select to activate the device connected to the 12V TRIGGER B terminal when the input source is selected.

Off: Select when no device is connected to the 12V TRIGGER B terminal or you do not want the connected device to activate.

6 Press the Setup button to return to the main menu.

Making Full Use of Your DTR-7.4

71

Page 71
Image 71
Integra DTR-7.4 Configuring the 12V Trigger Terminal, When the “Basic Menu” is displayed, select, “Advanced Menu.”