Intel386™ EX EMBEDDED MICROPROCESSOR USER’S MANUAL
D-58
D.58 SSIOBAUD
SSIO Baud-rate Control
SSIOBAUD
(read/write)
Expanded Addr:
ISA Addr:
Reset State:
F484H
00H
7 0
BEN BV6 BV5 BV4 BV3 BV2 BV1 BV0
Bit
Number Bit
Mnemonic Function
7 BEN Baud-rate Genera tor Enable:
Setting this bit enables the baud-rate generator. Clearing this bit disa bles
the baud-rate generator, clears the baud-rate count value, and forces the
baud rate clock to zero.
6–0 BV6:0 Baud-rate Value:
The baud-rate value (BV) is the reload value for the baud-rate
generator’s seven-bit down count er. The baud-rate generator’s output is
a function of BV and the baud-r ate generator’s input (BCLKIN), a s
follows.
(Hz)
If you know the desired output b aud-rate frequency, you can determine
BV as follows.
baud-rate output frequenc y (Hz) BCLKIN
2BV 2+
----------------------=
BV BCLKIN
2 baud-rate output frequency×
---------------------------------------------------------------------------------


1=