Networking Silicon — 82555
Symbol | Parameter Description | Condition | Min | Typ | Max | Units |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
c | Current on all VCC pins |
|
| 235 |
| mA |
ICC100 |
|
|
| |||
ICCT100TOT | Total supply current |
|
| 275 |
| mA |
a.Transmitter current is measured with a 1:1 transformer on the center tap.
b.Transmitter current is measured with a 1:1 transformer on the center tap.
c.Current is measured on all VCC pins at VCC = 5.25 V.
Rbias100
6 6 7 Ω
6 3 4 Ω
3 8 m A | 4 0 m A | 4 2 m A Icct100 |
6 0 4 Ω |
|
|
Figure 12. RBIAS100 Resistance versus ICCT100
11.4AC Characteristics
Output Levels |
| Input Levels | |||||||||||||||||||||||||||||||||||||||
VOH = 2.4 V |
|
|
|
| VIH = 2.0 V |
|
|
|
|
|
|
| |||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
VOL = 0.45 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VIL = 0.8 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 13. AC Testing Level Conditions
11.4.1MII Clock Specifications
| Symbol | Parameter | Conditions | Min | Typ | Max | Units |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T1 | TP100 | TXC/RXC period | 100 Mbps |
| 40 |
| ns |
T2 | TP10 | TXC/RXC period | 10 Mbps |
| 400 |
| ns |
T3 | TPMDC | MDC clock period |
| 400 |
|
| ns |
T4 | TTXDC | TXC duty cycle |
| 35 |
| 65 | % |
T5 | TRXDC | RXC duty cycle |
| 35 |
| 65 | % |
T6 | TMDC | MDC duty cycle |
| 35 |
| 65 | % |
Datasheet | 45 |