BIOS Intel® Server Board SDS2
Revision 1.2
Order Number: A85874-002
40
Sensor
Name
Sensor
#
Sensor Type
Event/
Reading
Type
Event
Offset
Triggers
Power Unit
Status 01h Power Unit -
09h Sensor
Specific - 6Fh
Power Off,
Power Cycle,
A/C Lost,
Power Unit
Redundancy 02h Power Unit -
09h Generic 0Bh Redundancy Regain
Redundancy lost
Watchdog 03h Watchdog2
23h Sensor
Specific - 6Fh
Timer Expired,
Hard Reset,
Power Down,
Power Cycle,
Timer Interrupt
Platform
Security
Violation 04h
Platform
Security
Violation
Attempt - 06h
Sensor
Specific - 6Fh
- Secure mode
violation attempt,
- Out-of-band access
password violation
Physical
Security
Violation 05h Physical
Security - 05h Sensor
Specific - 6Fh
General Chassis
Intrusion,
LAN Leash Lost
POST Error 06h System
Firmware
Progress 0Fh
Sensor
Specific - 6Fh POST error
FP Diag
Interrupt (NMI
for IA-32, INIT
for IA-64)
07h Critical
Interrupt - 13h Sensor
Specific - 6Fh Front Panel NMI
Memory 08h Memory 0Ch Sensor
Specific - 6Fh
Correctable ECC,
Uncorrectable ECC
Event
Logging
Disabled 09h Event Logging
Disabled 10h Sensor
Specific - 6Fh
Correctable Memory
Error Logging
Disabled,
Log Area
Reset/Cleared
BB +1.25V 0Ah Voltage 02h Threshold -
01h -
BB +2.5V 0Bh Voltage 02h Threshold -
01h -
BB +3.3V 0Ch
Voltage 02h Threshold -
01h -
BB +3.3V
Standby 0Dh
Voltage 02h Threshold -
01h -
BB +5V 0Eh Voltage 02h Threshold -
01h -
BB +12V 0Fh Voltage 02h Threshold -
01h -