Intel® Server Board SDS2

 

 

 

 

 

 

 

 

 

 

BIOS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

 

Sensor #

 

Sensor Type

 

 

Type

 

 

Triggers

 

 

 

 

 

 

 

 

 

 

Event/

 

 

Event

 

 

 

Sensor

 

 

 

 

 

 

Reading

 

 

Offset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presence,

 

 

 

Power

 

5Bh

 

Power Supply -

 

 

Sensor

 

 

Failure,

 

 

 

Supply 2

 

 

08h

 

 

Specific - 6Fh

 

 

Predictive Fail,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/C Lost

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presence,

 

 

 

Power

 

5Ch

 

Power Supply -

 

 

Sensor

 

 

Failure,

 

 

 

Supply 3

 

 

08h

 

 

Specific - 6Fh

 

 

Predictive Fail,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/C Lost

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Missing CPU

 

5Eh

 

Module/Board

 

 

Digital

 

 

State Asserted

 

 

 

Module

 

 

– 15h

 

 

Discrete - 03h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presence,

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal Trip,

 

 

 

Proc 1 Status

 

5Fh

 

Processor -

 

 

Sensor

 

 

IERR,

 

 

 

 

 

 

 

 

 

FRB1,

 

 

 

 

 

07h

 

 

Specific - 6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

FRB2,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRB3,

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presence,

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal Trip,

 

 

 

Proc 2 Status

 

60h

 

Processor -

 

 

Sensor

 

 

IERR,

 

 

 

 

 

 

 

 

 

FRB1,

 

 

 

 

 

07h

 

 

Specific - 6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

FRB2,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRB3,

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Status

 

 

 

DIMM 1

 

68h

 

Slot Connector

 

 

Sensor

 

 

Asserted,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 21h

 

 

Specific - 6Fh

 

 

Device Installed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Status

 

 

 

DIMM 2

 

69h

 

Slot Connector

 

 

Sensor

 

 

Asserted,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 21h

 

 

Specific - 6Fh

 

 

Device Installed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Status

 

 

 

DIMM 3

 

6Ah

 

Slot Connector

 

 

Sensor

 

 

Asserted,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 21h

 

 

Specific - 6Fh

 

 

Device Installed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Status

 

 

 

DIMM 4

 

6Bh

 

Slot Connector

 

 

Sensor

 

 

Asserted,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 21h

 

 

Specific - 6Fh

 

 

Device Installed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Status

 

 

 

DIMM 5

 

6Ch

 

Slot Connector

 

 

Sensor

 

 

Asserted,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 21h

 

 

Specific - 6Fh

 

 

Device Installed,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision 1.2

 

 

 

 

 

 

 