Intel® Server Board SDS2 | Jumpers |
2.Power off the system, unplug the power cord, and remove the chassis panel.
3.Add a jumper on CN42 pins
4.Insert the BIOS Recovery floppy diskette into the disk drive.
5.Reinstall the chassis panel; plug in the power cord(s), and power on the system.
6.The screen will remain blank while the BIOS Recovery is performed. At the end of the BIOS Recovery, two
7.Power off the system, unplug the power cord(s), and remove the chassis panel.
8.Remove the BIOS Recovery jumper from CN42 pins
9.Replace the chassis panel; plug in the power cord(s), and power on the system.
9.2.3Performing BMC Force Update
In the event of a release of an updated BMC Firmware, the following procedure may be used to update the Firmware.
1.Prepare a bootable floppy diskette containing the updated BMC firmware files for the SDS2 Server Board obtained from Intel’s web sites.
2.Power off the system, unplug the power cord, and remove the chassis panel.
3.Add a jumper on CN49 pins
4.Insert the BMC Firmware floppy diskette into the disk drive.
5.Reinstall the chassis panel; plug in the power cord(s), and power on the system.
6.If any POST errors occur, press F1 to continue. BMC Firmware update may take several minutes to complete. When the BMC Firmware update is complete, it is safe to power off the system.
7.Power off the system, unplug the power cord(s), and remove the chassis panel.
8.Remove the BMC Force Update jumper from CN49 pins
9.Replace the chassis panel; plug in the power cord(s), and power on the system.
Note: The instructions for BMC Force Update are general guideline. Please follow the specific instructions described in the release notes.
Revision 1.2 | 93 |
Order Number: |