Intel® Server Board SDS2

Errata Listing

Workaround:

This issue does not occur when the SDS2 onboard SCSI controller option ROM

 

is set to “Disabled”. To disable the SDS2 onboard SCSI controller option ROM,

 

access the Intel® Server Board SDS2 BIOS Setup by pressing F2 during

 

POST. In BIOS Setup, change the Advanced à PCI Configuration à

 

Embedded SCSI à Option ROM Scan option to “Disabled”.

 

Status:

Fixed. This issue is fixed in SDS2 BIOS Production Release 2.5 (Build 48) and

 

later versions.

 

15.SDS2 Build Your Own (BYO) Platform Confidence Test (PCT) v. 1.00 fails on the first run

Problem:

The first time the SDS2 BYO PCT v. 1.00 is run on an SDS2 system following a

 

cold boot, the following error message will be encountered:

 

***ERROR BMC.CHECKCHASSISSTATUS V4.11.1.0107

 

Chassis Status miscompared with known values.

 

EXP: 210101h, RCVD: 210001h, MASK: FFFFFFFFh

 

Standard Error Code = 0BE1501F

 

BMC.CHECKCHASSISSTATUS FAILED

 

This issue is not seen if the SDS2 BYO PCT v. 1.00 is re-run a second time

 

without restarting the system, or after restarting the system with a Ctrl-Alt-Del

 

warm boot.

Implication:

The SDS2 PCT v. 1.00 will fail with the BMC Check Chassis Status test when

 

the test is run following a cold boot.

Workaround:

None.

Status:

Fixed. This issue is due to the SDS2 BYO PCT v. 1.00 incorrectly identifying an

 

error condition. This issue has been fixed in SDS2 BYO PCT v. 1.01. SDS2

 

BYO PCT v. 1.01 will be added to the SDS2 system resource CD-ROM in

 

future engineering change order (ECO).

16.SDS2 0B71: System Temperature out of the range POST message

Problem:

When the SDS2 server board is installed in the SC5100 chassis, if the SC5100

 

front panel cable is disconnected from the SDS2 server board and then

 

reconnected while 5V standby voltage is applied to the system (AC power cord

 

connected to the system), the following message will be seen during POST the

 

next time the system is powered on:

 

System Monitoring Check

 

0B71: System Temperature out of the range

 

(Press <F1> to override boot suppression, or <F2> to enter Setup)

 

 

Revision 1.2

115

 

Order Number: A85874-002

Page 126
Image 126
Intel manual SDS2 0B71 System Temperature out of the range Post message, Revision 115 Order Number A85874-002