Hereare the configurations of CFM on the customer routers.
CFMon L2-CE1 [editinterfaces]
ge-0/2/9{
vlan-tagging;
unit0 {
vlan-id2000;
}
}
[editprotoccols oam ethernet]
connectivity-fault-management{
maintenance-domaincustomer {
level7;
maintenance-associationcustomer-site1 {
continuity-check{
interval1s;
}
mep700 {
interfacege-0/2/9.0;
directiondown;
auto-discovery;
}
}
}
}
CFMon L2-CE2 [editinterfaces]
ge-1/0/7{
vlan-tagging;
unit0 {
vlan-id2000;
}
}
[editprotoccols oam ethernet]
connectivity-fault-management{
maintenance-domaincustomer {
level7;
maintenance-associationcustomer-site2 {
continuity-check{
interval1s;
}
mep800 {
interfacege-1/0/7.0;
directiondown;
auto-discovery;
}
}
}
}
Hereare the configurations of CFM on the provider routers.
CFMon PE1 [editinterfaces]
ge-5/0/9{
113Copyright© 2010, Juniper Networks,Inc.
Chapter10: IEEE 802.1ag OAM Connectivity-FaultManagement