OPERATION OF THE SYSTEM | WTC 600 LP / MP |
3 Operation of the System
3.1Assembly and Starting Operation
Assembly | Chapter | |
|
| |
Checking the scope of delivery (delivery note) |
| |
|
| |
Placing the equipment in the |
| |
|
| |
Connecting the untreated water to the WTC 600 LP/MP; connecting | 2.2, 3.3.2.1, 3.3.1 | |
the WTC 600 PI in between, if required (depending on delivery scope) |
| |
|
| |
Installing the piping for backwashing and drinking water | 2.2 | |
|
| |
Installing the float switch | 3.3.2.4 | |
|
| |
Filling and connecting the sand filter and the activated carbon filter | 3.4.2 | |
|
| |
Connecting the electrical system | SLP, 3.3.2 | |
|
|
|
Table 8 | Assembly work to be carried out upon starting operation |
|
Starting Operation | Chapter | |
|
| |
Establishing the untreated water supply | 2.2 | |
|
| |
Manually actuating the sand filter backwashing | 3.4.2 | |
|
| |
Manually actuating the activated carbon filter backwashing | 3.4.2 | |
|
| |
Flushing the reverse osmosis | 3.4.3.7 | |
|
| |
Filling the chemicals container | 3.2 | |
|
| |
Adjusting the flow rates | 3.4.3.8 | |
|
| |
Filling out the metering table in the operating instructions |
| |
|
| |
|
| |
Instructing the operator (operating instructions) |
| |
|
|
|
Table 9 | Overview of |
|
A water analysis with the following values must exist for commissioning of the WTC 600:
-Total hardness GH in °dH
-Iron Fe in mg/l
-Manganese Mn in mg/l
-Ammonium NH4 or NH3 in mg/l
-System yield determined by the sales department (Normal case: 75%, in special cases 50%).
20 | Service Handbook 08.2004 |